Spirometry Solutions from Pulmonary Exchange, Ltd

Quick Guide

Spirobank-USB-Win spiroexpress software
  • Simple to use providing instant high quality printouts
  • Reusable and Disposable Turbine available
  • Measures the most important spirometric parameters
  • VC, IVC, FVC, FEV1, FEV6, FEV1/FVC%, PEF, FEF25-75%,FIVC, ELA (Lung age estimation)
  • Spirometry interpretation with traffic light indication
  • Internal temperature sensor for BTPS conversion
  • winspiro Express PC Software included
  • USB PC connection for printout and calibration
  • Upgradable internal software
  • Extremely simple to use.
  • Printout
  • Spirometry results with Flow/Volume loop and Volume/time curve can be printed in PDF format.
  • Each report is automatically saved complete with patient name and personal data.
  • Calibration
  • Simple calibration procedure for reusable turbine.
  • A calibration report complete with data and graphs can be printed as well.

Measured Parameters: Forced vital capacity: FVC, FEV1, FEV6, FEV1/FVC%, PEF, FEF25-75%, ELA

Spirometer Technical specifications

  • Temperature sensor: semiconductor (0-45°C)
  • Flow sensor: bi-directional digital turbine
  • Max volume: ± 10 L
  • Flow range: ± 16 L/s
  • Volume accuracy: ± 3% or 50 mL, whichever is greater
  • Flow accuracy: ± 5% or 200 mL/s, whichever is greater
  • Dynamic resistance at 12 L/s: <0.5 cmH2O/L/s
  • Display: 120 x 32 pixel, graphic LCD
  • Keyboard: 5 Keys
  • Connectivity: USB
  • Power Supply: 9V DC (PP3 battery)
  • Dimension: 162 x 49 x 34 mm
  • Weight: 180 grams battery included

winspiroPRO

PC system requirements Microsoft Windows 32bit: Vista, 2000, XP Screen resolution: 1024 x 768, Hard disk space required: 160MB, USB socket available, Adobe® Reader® PC Software

$520.00
includes 1 box of disposable tubines

Quick Guide

Spirobank G - USB - Bluetooth - Winspiro pro software
  • Stand alone spirometer with PC online operation.
  • 6000 spirometry in memory
  • High legibility graphic display
  • FVC, VC, IVC, MVV, PRE-POST BD
  • Advanced spirometry test interpretation
  • Lung age estimation
  • Direct printer connection via Bluetooth®
  • Ready for Telemedicine applications
  • Internal temperature sensor for automatic BTPS
  • Upgradable internal software via internet
  • Used worldwide by over 50,000 physicians
  • On line PC connection with icon-based interface
  • Real time Flow/Volume and Volume/time curves
  • PRE-POST bronchodilator comparison
  • Advanced spirometry test interpretation
  • Lung age estimation
  • Paediatric incentive animations
  • Bronchial challenge test with FEV1 dose-response curve
  • Several sets of predicted values
  • Data export also via e-mail
  • Integration with Electronic Medical Record
Parameters
  • Measured Forced vital capacity: FVC, FEV1, FEV1/FVC%, FEV6, FEV6%, PEF, FEF25, FEF50, FEF75, FEF25-75, FET, Vext, *FVC, *FEV1, *PEF, FIVC, FIV1, FIV1/FIVC%, PIF
  • Slow vital capacity: VC, IVC, IC, ERV, FEV1/VC%
  • Breathing pattern: VT, VE, Rf, ti, te, ti/ttot, VT/ti
  • Max voluntary ventilation: MVV
  • (* Best value)

Spirometer Technical specifications

  • Temperature sensor: semiconductor (0-45°C)
  • Flow sensor: bi-directional digital turbine
  • Max volume: ± 10 L
  • Flow range: ± 16 L/s
  • Volume accuracy: ± 3% or 50 mL, whichever is greater
  • Flow accuracy: ± 5% or 200 mL/s, whichever is greater
  • Dynamic resistance at 12 L/s: <0.5 cmH2O/L/s
  • Display: 120 x 32 pixel, graphic LCD
  • Keyboard: 5 Keys
  • Connectivity: USB and Bluetooth®
  • Power Supply: 9V DC (PP3 battery)
  • Dimension: 162 x 49 x 34 mm
  • Weight: 180 grams battery included

winspiroPRO

PC system requirements Microsoft Windows: Vista, 2000, Me, XP, 98 (Second Edition), Screen resolution: 1024 x 768, Hard disk space required: 160MB, USB socket available

$1195.00

 

Quick Guide

Spirobank 2 - USB - Bluetooth - win spiro pro software
  • Spirometer with 6000 test memory.
  • Oximeter with 1000 hours recording.
  • Stand alone or PC online operation.
  • Graphic display with user friendly icons.
  • Patient identification by name or ID code.
  • Bluetooth® connection to printer or mobile phone.
  • USB, RS232 and wireless acoustic modem.
  • Upgradeable internal software via internet.
  • FVC, VC, IVC, MVV, PRE-POST BD.
  • Automatically records the best 3 trials.
  • Internal temperature sensor for automatic BTPS.
  • Advanced spirometry test interpretation.
  • Lung age estimation.
  • Sleep disorder detection with events recording.
  • Six minute walk test with automatic alarm for rest, walk and recovery.
  • Parameters directly shown on the display (min, max, mean SpO2 and Pulse Rate, ? Index, T90, T89, T88, T5, ODI, NOD, Desaturation Area etc.).
  • Its innovative functions make it the most unique oximeter on the market
  • Spirometry program
  • Flow/Volume and Volume/time curves.
  • PRE-POST bronchodilator comparison.
  • FEV1 dose-response curve.
  • Exclusive paediatric incentive system.
  • Advanced spirometry test interpretation.
  • Several sets of predicted values.
  • Integration with Electronic Medical Record.
  • Data and graphs export also via e-mail.
  • Oximetry program
  • PC online with SpO2 and Pulse Rate trend.
  • Desaturation events analysis.
  • Possibility to modify the registered data (start/end walk test phase, artefacts, etc.).
  • One of the most distinctive elements of the spirobank II is the "specialised and detailed" printout in colour, which is easy to read and facilitates the diagnostic interpretation
Spirometer Technical specifications spirobank II base unit
  • Measured values: FVC, FEV1, FEV1/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25-75%, FET, Vext, FIVC, FIV1, FIV1/FIVC%, PIF, *FVC, *FEV1, *PEF, VC, IVC, IC, ERV, FEV1/VC%, VT, VE, Rf, ti, te, ti/t-tot, VT/ti, MVV (* = Best value).
  • Temperature sensor: semiconductor (0-45°C)
  • Flow sensor: bi-directional digital turbine
  • Flow range: ± 16 L/s
  • Volume accuracy: ± 3% or 50 mL, whichever is greater
  • Flow accuracy: ± 5% or 200 mL/s, whichever is greater
  • Dynamic resistance at 12 L/s: <0.5 cmH2O/L/s
  • Display: graphic LCD - FSTN, 128x64 pixel
  • Keyboard: membrane, 6 Keys
  • Communication port: USB, Bluetooth®, and RS232
  • Bluetooth profile: service discovery application, generic access, serial port
  • Power Supply: 4 x 1.5 V, AAA battery. On line mode USB PC connected Spirobank II is supplied directly by the PC
  • Dimension: 60 x 145 x 30 mm
  • Weight: 180 grams (battery included)

Option: Digital Oximeter

  • SpO2 range: 0-99%
  • SpO2 accuracy: ± 2% between 70-99% SpO2
  • Pulse Rate range: 30-254 BPM
  • Pulse Rate accuracy: ± 2 BPM or 2%, whichever is greater
  • Measured parameters:
  • Basic: SpO2 [Baseline, Min, Max, Mean], Pulse Rate [Baseline, Min, Max, Mean], T90 [SpO2<90%], T89 [SpO2<89%], T88 [SpO2<88%], T5 [?SpO2>5%], ? Index [12s], SpO2 Events, Pulse Rate Events [Bradycardia, Tachycardia]
  • 6 Minute Walk Test: T?2 [SpO2=2%], T?4 [?SpO2=4%], Recording time, Time [Rest, Walking, Recovery], Walked Distance, Predicted Distance [Min, Standard], Desaturation Area/Distance, Borg Dyspnea [Baseline, End, Change], Borg Fatigue [Baseline, End, Change]
  • Sleep Test: Desaturatin Events, Desaturation Index (ODI), Desaturation [Value, Duration, Nadir], ?SpO2 [Min Drop, Max Drop], Pulse Variations, Pulse Rate Index, NOD 89 [SpO2<89%; >5 min], NOD 4 [SpO2 Baseline-4%; >5 min], NOD 90 [SpO2<90%; Nadir <86%; >5 min]

PC system requirements Microsoft Windows 98 (Second Edition), NT 4.0, 2000, Me, XP, Minimum CPU clock 300 Mhz, Minimum RAM: 64 MB (128 MB on Windows NT), Recommended RAM: 128 MB, USB socket available (RS 232 option), Screen resolution 1024 x 768, Hard disk space required: 160MB

$1590.00

 

Quick Guide

Spirolab III - USB - Bluetooth - win spiro pro
  • FVC, VC with breathing pattern plus MVV tests with real time curves
  • High resolution colour screen
  • Fast but silent thermal printer
  • Digital turbine flow meter with guaranteed accuracy in all environmental conditions
  • PRE-POST bronchodilator comparison
  • Selectable language and predicted values
  • Connectivity: USB, Bluetooth® and RS232
  • Records best 3 trials.
  • Up to 8 blows on one screen.
  • Internal temperature sensor for BTPS conversion.
  • Short or long term (overnight) SpO2 and Pulse Rate measurements.
  • ODI, NOD, T90%, T89%, T88, T87%
  • Sleep oximetry with desaturation events.
  • Oximetry during exercise test.

Technical specifications Parameters:
  • (* Best value) FVC, FEV1, FEV1/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25-75%, FET, Vext, FIVC, FIV1, FIV1/FIVC%, PIF, *FVC, *FEV1, *PEF, VC, IVC, IC, ERV, FEV1/VC%, VT, VE, Rf, ti, te, ti/t-tot, VT/ti, MVV
  • Power supply: Rechargeable battery and mains power
  • Temperature sensor: Semiconductor (0-45° C)
  • Flow/volume transducer: bi-directional digital turbine
  • Flow range: ± 16 Ls
  • Volume accuracy: ± 3% or 50 mL
  • Flow accuracy: ± 5% or 200 mL/s
  • Dynamic resistance: <0.5 cmH2O/L/s
  • Connectivity: USB, Bluetooth, RS 232
  • Display: FSTN graphic, 320 x 240 pixel
  • Printer/paper: Thermal, 112 mm width
  • Mouthpieces: 30 mm external diameter
  • Dimensions: 310 x 205 x 65 mm
  • Weight: 1,9 Kg circa
  • Carryng-case: included

Finger Oximeter Technical specifications

  • (option) SpO2 range: 0-99%
  • SpO2 accuracy: ± 2% between 70-99% SpO2
  • Pulse Rate range: 30-254 BPM
  • Pulse Rate accuracy: ± 2 BPM or 2%

winspiroPRO software SpO2 and Pulse Rate graphic trend Flexible reporting with several printout categories Statistical analysis of desaturation events

PC system requirements Microsoft Windows 98 (Second Edition), NT 4.0, 2000, Me, XP, Minimum CPU clock 300 Mhz, Minimum RAM: 64 MB (128 MB on Windows NT), Recommended RAM: 128 MB, USB socket available (RS 232 option), Screen resolution 1024 x 768, Hard disk space required: 160MB

$2800.00

 

MIROxi
  • MIROxi surpasses the limits of all conventional instruments
  • which can only record SpO2 and Pulse Rate.
  • Its extensive and innovative integrated functions make it
  • the most unique oximeter on the market!
  • Up to 1,000 hours recording (2 or 4 seconds intervals)
  • Direct printer connection via Bluetooth®
  • Test data can be archived and then recalled using patient name
  • Graphic display with user friendly icons and messages to facilitate use
  • On-line PC connection with icon interface
  • Internal memory. with back-up of measured values, for up to 10 years even in absence of batteries
  • Data and graphs export also via e-mail
  • MIR Oxi calculates all parameters referred to in peer reviewed scientific literature and all principal “specific” statistical indexes by typology of test (ie: min, max, mean SpO2 and Pulse Rate, Delta Index, T90%, T89%, T88%, T87%, ODI, NOD, etc.).
  • All parameters are shown on the display without the need to connect to a PC.
  • Possibility to insert “extra-oximetry” data (ie: dyspnea, fatigue, distance) for automatic calculation of special diagnostic indexes such as the AUC/Distance (Area Under the Curve/Walked Distance) which are very useful to compare two different walk tests carried out by the same patient.
  • Sleep oximetry with desaturation analysis
  • 6 Minute Walk Test (6MWT)
  • Short and long term SpO2/BPM recording
  • Real time test on PC
  • Parameters Basic parameters: SpO2 (Baseline, Min, Max, Mean), Pulse rate [Baseline, Min, Max, Mean], T90 [SpO2<90%], T89 [SpO2<89%], T88[SpO2<88%], T87[SpO2<87%], SpO2 Events, Pulse Rate Events [Bradycardia, Tachycardia], ? Index [12s]
  • 6 Minute Walk Test Specific Parameters: T?2 [SpO2=2%], T?4 [?SpO2=4%], Recording time, Time [Rest, Walking, Recovery], Walked Distance, Predicted Distance [Min, Standard], AUC/Distance, Borg Dyspnea [Baseline, End, Change], Borg Fatigue [Baseline, End, Change]
  • Sleep Test Specific Analysis: Total Desaturatin Events, Desaturation Index (ODI), Desaturation [Mean Value, Mean Duration, Longest Duration, Nadir Peak], ?SpO2 [Min Drop, Max Drop], Total Pulse Variations, Pulse Rate Index, NOD 4 [SpO2 Baseline-4%; >5 minutes], NOD 89 [SpO2<89%; >5 minutes], NOD 90 [SpO2<90%; Nadir <86%; >5 minutes]

Device Technical

  • Specifications Display: STN graphic, 128 x 64 pixels
  • Keyboard: Membrane, 6 Keys
  • Connectivity and data transmission: USB, RS232, Bluetooth®, acoustic coupling
  • Power Supply: 4 x 1.5 V, AAA battery
  • Dimension: 106 x 62 x 26 mm
  • Weight:
  • 160 grams (battery included)
  • SpO2 range: 0-99%
  • SpO2 accuracy: ± 2% between 70-99% SpO2
  • Heart Rate range: 30-254 BPM
  • Heart Rate accuracy: ± 2 BPM or 2%, whichever is greater

$1200.00

 

Oxipulse
  • Sensor and display are combined in a pocket sized, lightweight device in which the patient directly inserts his finger.
  • OXI-PULSE is small in dimension - big in performance.
  • Its versatility makes it ideal in any situation in which an accurate measurement is required - ideal both for the doctor as well as the patient for homecare use.
  • SpO2 and Pulse Rate are visualised on an LED display using large characters easy to read even in dark environments.
  • Long battery life due to automatic switching off after 8 seconds when not in use.
Technical specifications
  • SpO2 Reading: LED display 8mm (0.32”) high
  • Pulse Rate Reading: LED display 8mm (0.32”) high
  • Pulse Intensity Reading: LED Bar Graph display 8mm (0.32”) high
  • SpO2 measurement
  • Range: 0-99%
  • Accuracy: +/-2% between 70-99%
  • Average: 8 pulse beat
  • Pulse Rate measurement
  • Range: 30-254 bpm
  • Accuracy: +/-2% or 2 bpm
  • Average value: 8 secs
  • Power requirement: 2 x AAA alkaline batteries (type LR03)
  • Battery Life: 16 hours continuous use
  • 1400 spot checks (1 min on - 2 min off)
  • Dimension: 44,3 x 5,7 x 3,8 cm
  • 1,7” W x 2.25” H x 1.5” D
  • Weight: 85 grams (3 oz.) with batteries
  • Environment
  • Operating Temperature: 0°C - +55°C
  • Storage Temperature: -40°C - +75°C
  • Relative Humidity: 15% - 95%
  • Carrying-case: option
.
Turbines - 100 per box with
  • FlowMir disposable turbine for single patient use
  • High accuracy.
  • Easy to replace.
  • Very low cost.
  • Designed for use with MIR spirometers.
  • FlowMIR is factory calibrated.
  • Available in box of 100 pieces.
  • No maintenance – No filter – No problem.
  • Hygiene 100% guaranteed by single packaging.
. $150.00

 

MiniSpir - USB - SpO2 option -
  • Plugs directly into the USB socket on your PC
  • No batteries and no other connection required
  • Ideal and easy solution for custom made applications
  • FVC, VC, IVC, MVV, PRE-POST BD.
  • Internal temperature sensor for automatic BTPS conversion.
  • Available with disposable or reusable digital turbine flowmeters
  • MiniSpir calculates all parameters referred to in peer reviewed scientific literature (ie: min, max, mean SpO2 and Pulse Rate, Delta Index, T90%, T89%, T88%, T5 etc.)
  • Spirometry printout
  • Paediatric Incentive

.

Spirometer Parameters:
  • (*Best value) FVC, FEV1, FEV1/FVC%, FEV3, FEV3/FVC%, FEV6, FEV1/FEV6%, PEF, FEF25%, FEF50%, FEF75%, FEF25-75%, FET, Vext, Lung Age,
  • FIVC, FIV1, FIV1/FIVC%, PIF, VC, IVC, IC, ERV, FEV1/VC%, VT, VE, Rf, ti, te, ti/t-tot, VT/ti, MVV
  • Temperature sensor: semiconductor (0-45°C)
  • Flow sensor: bi-directional digital turbine
  • Flow range: ± 16 L/s
  • Volume accuracy: ± 3% or 50 mL
  • Flow accuracy: ± 5% or 200 mL/s
  • Dynamic resistance at 12 L/s: <0.5 cmH2O/L/s
  • Communication port: USB
  • Power Supply: line powered from USB port
  • Dimension: 52 x 128 x 26 mm
  • Weight: 70 grams
  • Carryng-case: included

Option: digital oximeter

  • SpO2 range:
  • 0-99%
  • SpO2 accuracy: ± 2% between 70-99% SpO2
  • Pulse Rate range: 30-254 BPM
  • Pulse Rate accuracy: ± 2 BPM or 2%

System Requirements: winspiroPRO, PC system requirements Microsoft Windows: Vista, 2000, Me, XP, 98 (Second Edition), Screen resolution: 1024 x 768, Hard disk space required: 160MB, USB socket available

$1400.00

 

Cable
  • USB cable (1.8 m) for the PC connection
  • Product code: 532365
  • May be used on:
  • spirolab III. spirobank USB. spirobank II. MiniSpir. MIROxi. Miscellaneus
. .
Noseclip - Bag 0f 100
  • Plastic noseclip
  • Product code: 910320
  • May be used on:
  • spirolab. spirolab II. spirolab III. spirobank. spirobank USB. spirobank G. spirobank II. spirotel. spirodoc. MiniSpir. MiniFlometer. Miscellaneus
. $49.00

 

Mouthpiece - disposable - 100 per box
  • Disposable paper adult mouthpiece, external diameter: 30 mm
  • Product code: 910300
  • May be used on:
  • spirolab. spirolab II. spirolab III. spirobank. spirobank USB. spirobank G. spirobank II. spirotel. spirodoc. MiniSpir. MiniFlometer.
. $21.00

 

 

Mouthpiece - Reuseable - 100 per box
  • Reusable plastic adult mouthpiece
  • Product code: 910305
  • May be used on:
  • spirolab. spirolab II. spirolab III. spirobank. spirobank USB. spirobank G. spirobank II. spirotel. spirodoc. MiniSpir. MiniFlometer.
. $29.00

 

Filter - 50 per box
  • Disposable Bacterial/Viral filter, singularly packed
  • Product code: 910302
  • May be used on:
  • spirolab. spirolab II. spirolab III. spirobank. spirobank USB. spirobank G. spirobank II. spirotel. spirodoc. MiniSpir. MiniFlometer.
. $120.00

 

Calibration Syringe
  • Calibration syringe, 3 liters
  • Product code: 919000
  • May be used on:
  • spirolab. spirolab II. spirolab III. spirobank. spirobank USB. spirobank G. spirobank II. spirotel. spirodoc. MiniSpir. MiniFlometer. Miscellaneus
. $395.00

 

Turbine -
  • Reusable turbine for long term operation
  • ATS/ERS certified
  • High accuracy
  • Long term stability
  • Easy to clean or sterilize
. $290.00